Shenyang Zkwell Corrosion Control Technology Co., Ltd
position: home >> Products >> Portable corrosion monitoring instruments

Anti-corrosion services

hot key words

contact us

Shenyang Zkwell Corrosion Control Technology Co., Ltd


Address: Room 501, No. 1, Hunnan Road, Hunnan New District, Shenyang

Zip code: 110180

Tel: 86-24-83812820 83812821 24516448

Fax: 86-24-24515331

E-mail: business@zkwell.com.cn 


Corrosion Inhibitor Fast Evaluator

  • category:Portable corrosion monitoring instruments

  • clicks:
  • pubdate:2016/10/28
  • inquiry
detail


ZKW881 Corrosion Inhibitor Fast Evaluator


ZKW881corrosion inhibitor fast evaluator adopts the measurement technique combining the theory of electrochemical weak polarization and the measurement technique of electrochemical AC impedance. The electrochemical parameter B can be accurately measured by using weak polarization technique, and theoretical errors caused by parameter B estimation by traditional linear polarization measurement can be avoided; with AC impedance measurement technique and high-frequency region measurement, it can effectively eliminate the effect of solution resistance IR drop, especially applicable to the corrosion environment with higher dielectric resistance.


By adopting four channel techniques, the instrument can evaluate four pharmaceuticals at one time, and directly measure the instantaneous and average values of each pharmaceutical corrosion rate and the variation curve of corrosion rate varying with time. With the curve, we can master the corrosion inhibition effect and the failure process of each pharmaceutical product, so it provides a fast and effective method to evaluate the corrosion inhibition performance of pharmaceuticals.


ZKW881corrosion inhibitor fast evaluator is widely used for the fast evaluation of laboratory corrosion inhibitor and the corrosion measurement of all aqueous solutions and water-bearing oil and gas.


Corrosion Inhibitor Fast Evaluator


Instrument performance indicators:

·Temperature: 0℃~40℃

·Relative humidity: ≤80%RH

·Input impedance: 1.5×1012Ω

·Measurement range of Ecorr : ±800mV

·Measurement range of dielectric resistance Rs: 10Ω~200KΩ?cm2, measurement error of stimulation system ≤3%

·Measurement range of polarization resistance Rp: 20Ω~500KΩ?cm2, measurement error of stimulation system ≤3%

·Measurement range of corrosion rate: 4×10-4~10mm/a (polarization area 1cm2)

·Measurement times of four channels completed one by one: 15 min


【Instrument standard configuration:】

NO.NameTypeQty
1Main unit of corrosion rate measurerZKW8811
2Nylon electrochemical electrode holderZKW820-M3-L804
3Cylindrical electrochemical electrodeZK8290-Material-S412
4CheckerZK8300/10K1
5Charger (12V-4A)GY4501
6Power cordsGY5701
7Test leadsZKW8511
8Communication lineZKW852 (aviation plug to DB9 serial port)1
9Instruction manualZKW8921
10CDZKW8931


Recently Viewed:

s
e
r
v
i
c
e
share
Welcome to our message
Please enter your message here,We will contact you as soon as possible。
Name
Contacts
phone
phone