Since the compensation precision inductance probe data collector
Corrosion monitoring instrument is corrosion monitoring system of data collection and storage unit, including ZK9800 type data acquisition unit, used for double inductance probe ZK9810 data collector, and used for offline storage type ZK9801 data recorder, can according to the actual need to choose to use.
ZK9800 since the compensation precision inductance probe data collector
Technical parameters:
Working voltage | 12~36VDC |
The data collection interval | ≥1 min(Interval can be set) |
Interval can be set | 0.5W |
Working temperature | -25℃~+70℃ |
Explosion-proof type | The Ann, flame-proof |
Protection grade | IP65 |
Data transmission way | RS485 |
installation | Through the adapter and connect the probe connection |
Packing parameters :
Weight(kg) | Size (mm) | ||
Instrument net weight | 2.4 | Size of instrument | φ110×120 |
A single gross weight packing | 2.90 | A single package sizes | 195×195×200 |
Four packing gross weight | 10.38 | Four package sizes | 390×390×205 |
Packing weight (8 sets) | 20.26 | Packing size eight | 390×390×410 |
Note: for carton packing materials
ZK9810 since the compensation precision inductance probe data collector
Technical parameters:
12~36VDC | |
The data collection interval | ≥1 min(Interval can be set) |
The power consumption of the instrument | 0.5W |
Working temperature | -25℃~+70℃ |
Explosion-proof type | The Ann, flame-proof |
Protection grade | IP65 |
Data transmission way | RS485、4-20mA |
installation | Through the adapter connected to the probe integration |
Temperature measurement function | have |
Packing parameters :
Weight(kg) | Size (mm) | ||
Instrument net weight | 2.4 | Size of instrument | φ110×120 |
A single gross weight packing | 2.90 | A single package sizes | 195×195×200 |
Four packing gross weight | 10.38 | Four package sizes | 390×390×205 |
Packing weight (8 sets) | 20.26 | Packing size eight | 390×390×410 |
Note: for carton packing materials
Recorder ZK9801 corrosion rate
Technical parameters:
Working voltage | 12V |
Working temperature | -25℃~70℃ |
Explosion-proof grade | Ex dⅡCT6 |
Explosion-proof grade | IP65 |
Data storage | 8192 group/collection interval 1 year for 1 hour and can collect data continuously |
Battery capacity | 8Ah Rechargeable lithium batteries |
Battery full power working time | ≥6Months (1 hour and collecting data at a time) |
Packing parameters:
Weight(kg) | Size (mm) | ||
Instrument net weight | 2.0 | Size of instrument | φ110×120 |
A single gross weight packing | 2.5 | A single package sizes | 195×195×200 |
Four packing gross weight | 8.78 | Four package sizes | 390×390×205 |
Packing weight (8 sets) | 17.06 | Packing size eight | 390×390×410 |